v dry cooler a ni a.

v dry cooler a ni a.

Server dry cooler with redundant fans leh modular design, computing center retrofits atana tha tak, hot-swappable components leh predictive maintenance theihna nei 24/7 uptime enkawl.

Product Thuhmahruai .

Server Dry Cooler chu computing center retrofits atan hman theih a ni.

product-1175-882

V-Type dry cooler hi high-efficiency heat dissipation for industrial settings atan engineer a ni. A danglam bik V-Shaped configuration hian leihnuai area a ti tam a, footprint a ti tlem a, space tlemte nei factory tan a tha hle. Aluminum fin leh copper tube hmanga siam niin, corrosion resistance tha tak leh thermal conductivity tha tak a pe a ni. Modular design hian scalability awlsam tak a siam thei a, heat load 50 kW atanga 5 MW thleng pawh a handling thei a ni. Chemical plant-ah chuan process fluids (glycol ang chi) chu a lum a, heat chu ambient air-ah a reject a, tui mamawhna-based cooling systems a awm tawh lo. Variable-speed fans te hian temperature inthlak danglam dan an siamrem a, energy hman dan chu 30% thlengin a tihtlem phah a ni. Galvanized steel frame leh IP55 protection nghet tak nen, boruak khirh tak tak a tuar thei a, pawn lama installation-a hnathawh chhunzawm zel theihna tur a ni.

 

Computing center retrofits atana siam, he server dry cooler hian 24/7 uptime a siam a, redundant fans, hot - swappable components, leh predictive maintenance te a awm bawk. Efficiency, reliability, leh modularity te a inzawm khawm a, data center-a heat dissipation challenges te chu sustainability goal nena inmil chungin a hmachhawn a ni.

 

Core Specifications 1.1.

 

Parameter 100 a ni.

Chipchiar

Modular design a ni a, a design pawh a tha hle.

Scalable module (50 kW – unit khatah 5 MW) a ni.

Fan chi hrang hrang .

A rilru a buai em em a, a rilru a hah em em bawk a. - swappable variable - speed fans

Thil hman tur .

corrosion - in leh lo insum thei lo; High - Conductivity Heat Exchanger Core 1000 vel a ni.

Energy hmanga sum khawl .

Variable - speed fan control hmangin 30% thleng a awm thei

Protection grade 1000 a ni.

IP55 (pawn lam boruak khirh tak tak a awm thei)

 

Product details .

 

1

Structural design & a chhe thei lo .

◆ Housing: High - grade, corrosion - resistant steel atanga siam a ni a, cooler-a housing hian data center environment-a - term durability rei tak a siam thei a ni. Temperature inthlak danglamna, leivut, leh tuihna tenau tak tak a awm loh nan a tuar thei a, in chhung leh pawn lama installation atan pawh a tha hle.
◆ Modular Unit: Modular unit tin hi 800mm (W) × 1200mm (D) × 1500mm (H) a ni a, kg 200 vel a rit (50 kW module) a ni. Compact size hian computing centre awmsa, hmun tlemte nei te pawh awlsam taka inzawmkhawm theihna a siam a ni. Module te chu parallel-a dah emaw, dahkhawm emaw theih a ni a, data center heat load a san chuan seamless scalability a awm thei bawk.

 

2

Thermal performance 1000 a ni.

◆ Heat Exchanger Core: Core hian aluminum fin leh copper tubes inzawmkhawm a hmang a, thermal conductivity a ti tam thei hle. Module khatah heat load 50 kW atanga 5 MW thleng a ti bo thei a, peak load laiin server temperature nghet (18℃– 27℃optimal range) a vawng reng thei bawk.

◆ Redundant fans: Cooler-ah hian dual redundant fans a awm a. Fan tin hian diameter 400mm an nei a, airflow sang ber chu 5000 m3/h a ni a, power consumption 150 W (full speed-ah) a nei bawk. Fan a chhiat chuan redundant unit hian second 0.5 chhungin a activate a, hei hian cooling interruption a veng thei a ni. Variable - speed control hian temperature sensor hmanga fan speed a siamrem a, - load period hniam laiin energy hmanna chu 30% thlengin a ti tlem thei a ni.

 

3

Maintenance & rintlakna .

◆ Hot - Components swappable: fans, sensor, leh minor components te hian hot - swapping an support a. Hei hian components te chu cooling system khar lovin a thlak theih tihna a ni a, 24/7 data center hnathawh a nih theih nan a enkawl thei tihna a ni. Fan replacement kimchang chu standard tools hmangin minute 10 aia rei lo a ngai a ni.
◆ Predictive Maintenance: Sensor-a siam - chuan fan speed, temperature differential, leh component vibration te a enfiah thin. System hian AI - driven algorithms hmangin a hlawhchhamna (eg, fan bearing wear, sensor drift) chu kar 2 hmain a hrilhfiah thei a ni. Maintenance alerts chu data center management system-ah thawn a ni a, off - peak hours (eg, late - zan emaw weekend emaw) chhunga scheduling siam theih a ni.

 

4

Energy efficiency & sustainability .

◆ Power consumption: Cooler-a power hman zawng zawng hi 50 kW module atan 150 W (Fan, Low Speed) atanga 300 W (Fan pakhat, full speed) thleng a ni. Variable - speed control a nih chuan, fixed - speed coolers nen khaikhin chuan power hman zat chu 30%-in a tlahniam a, kum khat chhunga energy save-naah module khatah $2,000–$5,000 a ni (0.15 $/kWh-a chhut).
◆ Tui - Free Cooling: Heat rejection atan ambient air hmangin cooler hian tui - based system mamawhna a ti bo a ni. Hei hian cooling atan tui hman zat 100% in a tihtlem a, data center-te sustainability goal nena inmil leh operational costs (tui treatment emaw plumbing maintenance awm lo) a tihtlem phah a ni.

 

5

A hman dan & a inmil theihna .

◆ Retrofit scenario: Legacy data center tihchangtlunna atana tha ber. Modular design hi rack layout awmsaah a fit a, compact size (800mm × 1200mm × 1500mm per module) chu repurposed industrial buildings emaw purpose - built facilities-ah a thawk thei bawk.

◆ A inmil theihna: Data center infrastructure hman tlanglawn (eg, Liebert, Delta Cooling Systems) nen a inzawm a ni. Direct leh indirect air - cooling architecture pahnih a support a, server layout hrang hrang tan flexibility a pe bawk.

 

6

Logistics & Delivery tih a ni bawk.

◆ Packaging: Module te chu thing crates (1200mm × 1000mm × 1800mm) ah an thawn a, anti - vibration padding an nei a, safe transit an nei thei a ni.
◆ Delivery hun: Standard lead time hi custom order tan chuan kar 4–6 a ni. - stock module (50 kW – 200 kW) te chu kar 1 chhungin an thawn chhuak thin.
◆ Installation: On - Site installation hian module khatah ni 1–2 vel a hmang a (wiring leh integration te pawh a tel), a siamtu technical team-te puihna nen.

hot tags .: V Dry Cooler, China v Dry Cooler siamtute, Supplier te, Factory te

Inquiry thawn rawh .

whatsapp

Biakhlatna

E-mail hmangin a rawn thawn a.

Chhuifiahna