Server dry cooler a ni a.

Server dry cooler a ni a.

v Dry cooler chu EC fans leh aluminum heat exchanger te nen, data center application atana engineer-in a siam a, variable-speed operation leh intelligent control system hmangin 30% energy saved a pe chhuak a ni.

Product Thuhmahruai .

v Data center cooling solution atan dry cooler a awm bawk.

product-1092-696

Server cooling atana optimized, he dry cooler hian IT hmanrua chu a lum lutuk loh nan a venghim a ni. Aluminum microchannel coil leh high-Static-pressure fans te hian data center coolant loop atanga heat removal tha tak a siam thei a ni. Modular design hian liquid cooling system hmanga seamless integration a siam thei a, unit khatah 1 MW thleng heat load a handling thei bawk. Colocation facility-ah chuan 18-27℃chhungin server inlet temperature a vawng reng a, thermal throttling leh hardware chhiatna a veng thei a ni. Intelligent control system hian server load a zirin fan speed a siamrem a, boruak nena khaikhin chuan energy hman dan 40% in a ti tlem zawk-cooled systems. Corrosion-resistant finish leh IP65 rating neiin, leivut emaw, boruak lum emaw-ah rintlak takin a thawk a, critical computing infrastructure-te dam chhung a ti rei zawk

 

Product details .

 

1

Brand & thu bulpui .

◆ Brand:Hylita .
◆ A siamna hmun:China .

◆ Certifications: CE, ISO 9001, Ashrae

◆ Model: V{{0}DC{{1}D1000 a ni.

 

2

Transaction & Procurement chungchang chipchiar takin .

◆ Pawisa pek dan tur: T/T (30% advance, thawn chhuah hma 70%), L/C hmuh theih

◆ Minimum order quantity (MOQ): 1 Unit (small-Batch testing support; unit 5 aia tam emaw, a tlukpui emaw order-a 5% discount)

◆ A man:
Unit pakhat (1- unit 4): $18,000-$22,000 (config-a innghat, control system fing tak a tel)
Bulk Order ( unit 5 aia tam emaw, a tlukpui emaw): $16,500-$20,000 (a tam thei ang bera siam theih, installation kaihhruaina nen)

 

3

Packaging leh logistics te pawh a awm bawk.

◆ Packaging:
Inner layer: Core components (aluminum heat exchangers, EC fans) te tan EPE pearl cotton wrapping a awm a, chu chuan a inhnaih loh nan a veng thei a ni.
Outer layer: Export-Grade plywood crates (ISPM 15 standards zawm), waterproof leh moisture-Tuipui/air transport atana proof.
◆ Inkalpawhna: 1.1.
Domestic: Deppon/SF cold chain (On-site installation service nen).
International: DHL/Maersk, CFR/FOB term thlawptu; Ram pawn lama warehouse tihhlawhtlinna (Europe & America-a ni 3 chhunga thawn chhuah).

◆ Lead time:
in-Stock models: Darkar 72 chhunga thawn chhuah.
Customized order: hnathawh ni 15-25 (intelligent control functions & appearance customization hnuaia awm).

 

4

Core Product Specifications 1.1.

Bithliahna

Specification 100 a ni.

Hrilhfiahna

Thil hman tur .

Main Frame 1000 a ni.

Galvanized stainless steel (corrosion-Data center environment-a hman theih loh)

 

Heat Exchanger 1000 a ni.

Aerospace-Grade aluminum microchannels (thermal conductivity sang, rit lo)

 

fans te .

EC variable-frequency fans (power hman tlem, speed zau tak siamrem)

Thuneihna

Fan power a awm em?

200-800 W (airflow hmanga fing taka siamrem; 50 W at no load thlenga hniam)

Buk

Unit khata net weight .

350-500 kg (heat load-a innghat; 1 MW model approx. 450 kg)

Dimension hrang hrang .

L×W×H

2200×1500×2000 mm (1 MW model, modular stacking a support)

Dilna fit a ni .

Heat load range a awm bawk.

200 kW-1 MW/unit (Multi-unit parallel expansion a thlawp)

 

Temperature control theihna hmun .

Coolant inlet: 15-35℃(18-27 degree-ah server inlet a vawng reng thei )

 

5

Core application scenario hrang hrangte .

◆ Data center hrang hrangte:
Colocation Facilities: Server inlet temperature (18-27℃) chu thermal throttling venna atan chiang takin a control a, high-density rack (eg, 42U blade server clusters) atan a tha hle.
Enterprise Server Rooms: AC system energy hman tlem nan liquid cooling system (eg, cold plate, immersion cooling) nen a inzawm tlat a ni.

◆ Edge computing node hrang hrang:
Pawn lam/Harsh Environment: IP65{{1}Rated, corrosion-resistant finish hian leivut, humidity, leh tui spray tenau (eg, telecom base station, industrial IoT hub) te a tuar thei lo.

 

6

Hnathawh pawimawh tak tak .

◆ thermal taka thermal enkawl dan: 1.1.
AI-Driven control system hian fan speed chu real-time server load (BMS/DCIM integration hmangin) hmangin a siamrem a, energy hman dan chu 40% vs. traditional air-cooled system-ah a tihtlem bawk.
Real-coolant flow, temperature, leh fan status te hun hman dan, anomalies (eg, clogging, motor failure) te alarm notification nen.

◆ High-Efficiency Heat Exchange:
Aluminum microchannel coils hian heat transfer coefficient 600 w/(m2·k) thleng a siam thei a, liquid atanga heat chu rang takin a ti bo thei-cooled server loops (eg, glycol-water mixtures).
High-Static-Pressure fans (airflow 8,000 m3/h thleng) Heat exchanger hrang hrangah boruak kal dan inang tlang siam la, high-backpressure ducting setup-ah pawh.

 

7

Product a thatna te .

◆ Energy Savings: 30-40% chu variable hmanga power hman tlem zawk-Speed ​​EC fans leh load-adaptive control, unit khatah $5,000-$8,000-a lehlin ($0.15/kWh-ah).

◆ Modular scalability: Hot-swappable module hian system downtime awm lovin incremental capacity expansion (eg, 200 kW increments) a phalsak a, data center pung zel atan a tha hle.

◆ Harsh environment-a rintlakna: IP65 Protection and Corrosion-resistant coating hian dusty server room emaw outdoor installation-ah emaw hnathawh chhunzawm zel a ti thei (MTBF darkar 80,000 aia tam emaw, a tlukpui emaw).

◆ Space optimization: Traditional shell{{1} leh-tube coolers aiin footprint 50% a te zawk a, tight data center aisle emaw raised floor emaw-ah a fit.

◆ Enkawlna hniam: Mahni self-Diagnostic control system hian kut hmanga enfiahna a ti tlem a; Fan leh coil module te hian support tool-free replacement an support a, downtime an tih tlem phah ( module khatah minute 30 aia tlem emaw a tlukpui emaw).

hot tags .: Server Dry Cooler, China Server Dry Cooler siamtute, Supplier te, Factory te pawh a awm nual.