Chiller evaporator a ni a.

Chiller evaporator a ni a.

Kan refrigeration copper coil, a sang - purity copper tubes leh fins te hian thermal conductivity danglam tak a pe a ni. Industrial freezer tan a tha em em a, rang takin refrigerant a ti lum a, Ultra - temperature hniam tak enkawlna leh energy - hnathawh dan tha tak a siam thei a ni.

Product Thuhmahruai .

High - velocity evaporator coil a awm a, chu chu data center cooling atan a ni.

product-1170-878

High-Velocity Evaporator Coil data center cooling atan.Data center hrang hrang tan design a ni a, he high-Velocity evaporator coil hian server exhaust air a ti lum nghal vat a ni. A densely packed copper tubes (10mm OD) leh ultra-thin aluminum fins (0.1mm) chuan turbulence a siam a, heat transfer chu 40% in a tichak a ni. Coil hi 150–300 kW cooling capacity-a rated a ni a, boruak sang (5000–10,000 m3/h) hnuaiah a thawk a ni. Assembly lai hian robotic brazing hian joint strength inang tlang tak a siam a ni. Server temperature 25℃aia hniam a neih chuan IT environment pawimawh takah chuan overheating leh system failure a veng thei a ni.

 

Data center hrang hranga siam, he - velocity evaporator coil hian thermal conductivity danglam tak pe chhuak turin - purity copper tube leh fins sang tak a hmang a ni. Server exhaust air chu rang takin a ti lum a, server temperature 25℃aia hniam a vawng reng a ni. Industrial freezer leh IT environment pawimawh tak tak tan a tha hle a, - temperature maintenance leh energy - efficient operation a ensure a, chutih rualin overheating leh system failure a veng thei bawk.

 

 

Product details .

 

1

Core components & materials te .

Component 1000 a ni.

Material/Specification .

Function & advantage .

Tubes 10 a awm.

- thianghlim tak copper tubes (10mm od) a ni.

Server exhaust atanga heat transfer rang thei tur thermal conductivity tha tak neih theih

fins .

Ultra - aluminum fins te tak te (0.1mm a thuk) a awm bawk.

Turbulence siam, cooling tha tak neih theih nan heat transfer 40% a tihpun

Cooling theihna .

150 - 300+ kW atan rated a ni.

Data Center Server Racks atan cooling tling tak a pe thei

 

2

Performance Parameters 1000 a ni.

◆ Heat Transfer Enhancement: Densely packed copper tubes leh ultra - thin aluminum fins chuan turbulence a siam a, heat transfer chu 40% in a tipung a, server exhaust air chu a ti lum nghal thei bawk.

◆ Airflow & Cooling: Airflow sang ({{0},000 m3/h) hnuaiah a thawk a, cooling capacity 150 - 300+ kW a nei a, server temperature 25℃aia hniam a vawng reng bawk.

◆ System humhalhna: IT environment pawimawh takah chuan overheating leh system failure te chu a veng a, server te temperature stable, hniam - a awm theih nan a veng thei a ni.

 

3

Structural design & efficiency .

◆ High - Velocity Design: Data center cooling atana optimized, high - velocity airflow (5000 - 10,000 m3/h) leh enhanced heat transfer (40% boost) hmangin server - siam chhuah chu rang taka paih chhuah theih a ni.

◆ Robotic Brazing: Assembly laiin uniform joint strength a awm theih nan a enkawl a, data center hnathawh chhunzawm zelna tur coil structure rintlak leh nghet tak a siam thei.

 

4

Application scenario hrang hrang .
A tha ber:

◆ Data Centres: Server exhaust air chu operating temperature tha ber (25℃hnuai lam) a awm theih nan a ti lum a, hmanrua a lum lutuk loh nan leh data processing tihtawp loh a nih theih nan a pui bawk.

◆ Industrial freezers: Refrigerant tihlumna rang tak a pe a, - temperature enkawlna leh energy - te chu freezing environment-a hnathawh dan tha tak a thlawp a ni.

 

5

A thatna pawimawh tak takte .

◆ Exceptional thermal conductivity: High - thianghlim copper tubes leh fins hmangin heat transfer rang tak a awm thei a, server exhaust air emaw refrigerant emaw chu a lum thei hle.

◆ Heat Transfer Boost: Ultra - aluminum fins te tak te hian turbulence a siam a, heat transfer chu 40% in a tipung a, overall cooling performance a ti sang bawk.

◆ High cooling capacity: 150 - 300+ kW atan rated a nih avangin data center server rack leh industrial freezer-a cooling demand te chu a handle thei a ni.

◆ System rintlakna: Server temperature 25℃aia hniam a vawng reng a, IT environment pawimawh takah chuan a lum lutuk leh system a chhiat loh nan a veng thei bawk.

 

6

Technical zawm dan .

◆ Data center cooling leh industrial refrigeration hmanrua atana industry standard a zawm. High - purity copper, ultra - thin aluminum fins, leh robotic brazing te hman hian thermal efficiency, durability, leh rintlak taka hman theihna tur mamawh a tlin a ni.

 

7

Packaging leh logistics te pawh a awm bawk.

◆ Packaging: Anti - static hmanga ven, shock - transit chhunga coil venhim nan materials absorbing. Duty industrial component rit tak tak - rit tak tak dahna tur crates nghet takah thawn chhuah a ni.

◆ Delivery time: A tlangpuiin order confirmation hnu ni hnathawh ni 8 - 18, order quantity a zirin. Freight carrier hmangin data center emaw industrial facility emaw ah thawn theih a ni.